{"id":11077,"date":"2025-04-25T11:19:43","date_gmt":"2025-04-25T06:49:43","guid":{"rendered":"https:\/\/teifsanje.com\/device-questions\/"},"modified":"2025-09-16T00:20:01","modified_gmt":"2025-09-15T19:50:01","slug":"device-questions","status":"publish","type":"post","link":"https:\/\/www.teifsanje.com\/en\/device-questions\/","title":{"rendered":"Device questions"},"content":{"rendered":"[vc_row row_type=&#8221;row&#8221; text_align=&#8221;left&#8221; css_animation=&#8221;&#8221;][vc_column][vc_empty_space][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">The device cannot communicate with the computer:<\/span><\/h4>\n<p style=\"text-align: left;\">The connection between the computer port and the device should be evaluated. A suitable USB cable should be used.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">The device does not turn on:<\/span><\/h4>\n<p style=\"text-align: left;\">Check the device&#8217;s fuse. Make sure to use a UPS to properly power the device and prevent the effects of city power fluctuations.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">When turning on the tungsten lamp of the optical device, it is not visible from the side of the fan:<\/span><\/h4>\n<p style=\"text-align: left;\">The tungsten lamp intensity is set to a low number. The lamp in the device is at the end of its life or has burned out.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">Lack of a proper baseline:<\/span><\/h4>\n<p style=\"text-align: left;\">Make sure the blank and sample use the same solvent or matrix.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">Scope baseline high:<\/span><\/h4>\n<p style=\"text-align: left;\">Wash the cell beforehand with a suitable solvent or, if necessary, with acid. The sample should not have suspended particles. There should be no bubbles in the sample (be sure to prepare a uniform sample before spectrometry by tapping the sample cell or giving it time to allow bubbles to escape and place it in the device.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">The bottom of the scope is not suitable:<\/span><\/h4>\n<p style=\"text-align: left;\">The tungsten lamp has low intensity or is not lit.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">The top of the scope is not suitable:<\/span><\/h4>\n<p style=\"text-align: left;\">It is necessary to adjust the deuterium lamp. If the intensity is not adequate, the deuterium lamp is off or burned out.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text]\n<h4 style=\"text-align: left;\"><span style=\"color: #003366;\">The shift in wavelength is observed:<\/span><\/h4>\n<p style=\"text-align: left;\">A spectrum is taken using a samarium or holmium standard sample and the calibration factor is corrected.<\/p>\n<p style=\"text-align: left;\">[\/vc_column_text][vc_separator type=&#8221;normal&#8221;][\/vc_column][\/vc_row][vc_row row_type=&#8221;row&#8221; text_align=&#8221;left&#8221; css_animation=&#8221;&#8221;][vc_column][vc_column_text]\n[\/vc_column_text][\/vc_column][\/vc_row]\n","protected":false},"excerpt":{"rendered":"<p>[vc_row row_type=&#8221;row&#8221; text_align=&#8221;left&#8221; css_animation=&#8221;&#8221;][vc_column][vc_empty_space][vc_column_text] The device cannot communicate with the computer: The connection between the computer port and the device should be evaluated. A suitable USB cable should be used. [\/vc_column_text][vc_separator type=&#8221;normal&#8221;][vc_column_text] The device does not turn on: Check the device&#8217;s fuse. Make sure to&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[22],"tags":[],"class_list":["post-11077","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/posts\/11077","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/comments?post=11077"}],"version-history":[{"count":4,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/posts\/11077\/revisions"}],"predecessor-version":[{"id":12173,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/posts\/11077\/revisions\/12173"}],"wp:attachment":[{"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/media?parent=11077"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/categories?post=11077"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.teifsanje.com\/en\/wp-json\/wp\/v2\/tags?post=11077"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}